SUPERVISED WIRELESS
SECURITY CONTROL PANEL
DUAL 824
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com
Installation & Programming Instructions
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,DUAL 824 - LINEAR P/N: 217703 D - INK: BLACK - MATERIAL: 20 LB. MEAD BOND WITH 80 LB. WHITE COATED COVER - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM FOLD - BINDING: SADDLE-STITCH
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - SECURITY CONTROL PANEL

SUPERVISED WIRELESSSECURITY CONTROL PANELDUAL 824USA & Canada (800) 421-1587 & (800) 392-0123(760) 438-7000 - Toll Free FAX (800) 468-1340www.

Page 2 - INTRODUCTION

8SYSTEM LOCATION✎ NOTE: Wireless sensor signals must be able to reach the Control Panel.✔ Try to centrally locate the Control Panel.✔ Keep Control

Page 3 - TABLE OF CONTENTS

9HARDWIRED KEYPAD INSTALLATION✦ One or two Model DUAL 824KP keypads can be used with the DUAL 824P Control Panel (one keypad is included in the DUAL

Page 4 - † NOTE: These accessories

10HARDWIRED LOOP WIRING✦ The DUAL 824 supports up to eight normally open/closed hardwired loops each with 2.2K end-of-line resistor supervision.✦ Ea

Page 5

11EXTERNAL ALARM SIREN CONNECTION✦ An external siren alerts occupants and neighbors with a loud siren during alarm.✦ Use a 12 volt, 1 amp maximum ra

Page 6

12AUTOMATION OUTPUT CONNECTION ✦ The Control Panel provides a Automation Output to control lights, devices and appliances.✦ Automation Output can co

Page 7 - 3. OVERVIEW OF KEYPADS

13CONTROL PANEL POWER CONNECTION✦ The Control Panel is powered by a low voltage plug-in transformer.✦ Use up to 25 feet of 20 AWG or larger 2-conduc

Page 8 - 4. HARDWIRED KEYPAD FEATURES

14✦ In a new installation, when power is fi rst applied the system's master user code is “1234”.CREATE THE MASTER USER CODE✎ NOTE: Local program

Page 9 - 5. CONTROL PANEL FEATURES

15PROGRAM THE HARDWIRED LOOPS✦ Each hardwired loop used must be programmed into the Control Panel's memory.✦ Each hardwired loop programmed use

Page 10 - 3/4" CONDUIT HUBS IN

16PROGRAMMING DIFFERENT SENSOR TYPES✦ Follow the instructions on the previous page to select a sensor number to program the sensor into.✎ NOTE: A se

Page 11

17PROGRAMMING DIFFERENT SENSOR TYPES (CONT.)✦ For DXT-61, DXT-21, DXS-21, DXT-41, & DXS-62A single-button remotes, simply press the unit's b

Page 12

CONGRATULATIONS for selecting Linear's DUAL 824 Security System. The Model DUAL 824P Control Panel and the Model DUAL 824KP Keypad incorporate ma

Page 13 - EXTERNAL

18✦ Each accessory sensor is packaged with its own set of installation instructions specifi c to the model of sensor.✦ Refer to the sensor's ins

Page 14 - MICROPHONE COMMON (-)

19DXS-31 & DXS-32 DOOR/WINDOW SENSORS✦ The DXS-31 and DXS-32 sensors can be used to monitor doors, windows, cabinets, crawl space doors, gates, f

Page 15 - ON THE MAIN TERMINAL

20✦ The system can be customized for the specifi c installation.✦ A label sheet with sensor location names is provided with DUAL 824KP keypads.✦ Lab

Page 16 - MASTER USER CODE:

21OFF MODE✦ Use this mode to disarm the burglary portion of the system.✦ The 24-hour functions are still active in Off Mode and can be triggered wit

Page 17

22HOME MODE✦ Use this mode when sleeping or when anyone is staying inside.✦ Home Mode causes an instant alarm when any perimeter sensor is triggered

Page 18

23AWAY MODE✦ Use this mode when no one will be staying home.✦ Away Mode causes an instant alarm when any perimeter sensor is triggered.✦ Away Mode

Page 19 - BOTH = EMERGENCY

24TEST MODE✦ Even though this is a self-monitoring supervised system, the National Burglar and Fire Alarm Association recommends that all security sy

Page 20 - 8. BASIC SENSOR INSTALLATION

25✦ The DUAL 824P Control Panel is a self-monitoring supervised wireless system. If the Control Panel detects a problem with any of the supervised sy

Page 21 - OPTION JUMPER

26✦ Adding additional sensors will increase the protection provided by the system.✦ All ground-level perimeter openings and accessible upper-story o

Page 22 - 9. CUSTOMIZING THE KEYPAD

27MAKING A SENSOR A 24-HOUR DOOR CHIME✦ Sensors can be programmed to cause the keypad(s) to chime any time they're activated.✦ Chime-only senso

Page 23 - 10. SYSTEM OPERATING MODES

11. THE DUAL 824 SECURITY SYSTEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CONTROL PANEL . . . . . . . . . . .

Page 24

28MAKING A SENSOR PERFORM A DIFFERENT FUNCTION✦ Sensors can be reprogrammed to perform different sensor functions.✦ The sensor must have already bee

Page 25 - TO AWAY MODE

29✦ To perform any of the advanced programming steps, the system must be in the Setup Mode.✦ Each programming function is performed with similar key

Page 26 - TEST MODE

30CHANGING A SENSORS SUPERVISION✦ When a wireless sensor is programmed, the Control Panel automatically sets it to supervised or non-supervised. The

Page 27 - TROUBLE INDICATOR

31FIRE SIREN TIME✦ The factory-set fi re siren time is fi ve minutes (UL installation maximum).STEP #32 The fi re siren time can be adjusted from one t

Page 28 - 12. CUSTOMIZING THE SYSTEM

32SILENT BURGLARY ALARMS✦ The factory setting causes audible burglary alarms.STEP #63 The Control Panel can be programmed for silent burglary alarms

Page 29

33AUTOMATION OUTPUT MODE DURING ALARM✦ The factory setting causes the Automation Output to fl ash if it is programmed to activate during or after an a

Page 30

34AUTOMATION OUTPUT WHILE ARMED✦ The factory setting causes the Control Panel's Automation Output to activate when pressing the key, or when it

Page 31 - 13. ADVANCED PROGRAMMING

35ADDING ADDITIONAL USER CODES✦ The Control Panel can be programmed with fi ve restricted user codes and one page alert user code.✦ The restricted us

Page 32

36✦ To perform any of the advanced programming steps, the system must be in the Setup Mode.✦ Each programming function is performed with similar key

Page 33

37GENERAL COMMUNICATOR OPTIONSCOMMUNICATOR ENABLE✦ The factory setting for the Control Panel disables the communicator. If the system is going to be

Page 34

2CONTROL PANELThe DUAL 824P Control Panel is the heart of the system. It monitors all of the system's wireless sensors, hardwired loops, and cont

Page 35

38CALL LIMITER✦ The factory setting for the call limiter is OFF. This allows the communicator to report burglary alarms, once for each sensor, as man

Page 36 - DURESS CODE:

39COMMUNICATOR REPORTING OPTIONSREPORTING FORMAT✦ The factory setting causes the communicator to report using the 4 BY 2 FORMAT. This format allows f

Page 37

40ACCOUNT NUMBER✦ The account number entered for the communicator must be 4-digits long.✦ The factory setting for the account number is 0000.STEP #8

Page 38 - 14. COMMUNICATOR PROGRAMMING

41REPORT CONTROL PANEL TROUBLE✦ The factory setting does not report Control Panel trouble events to the Central Station.STEP #108 The communicator c

Page 39

42COMMUNICATOR REPORTING CODES✦ The 4 by 2 two-digit communicator reporting code for each event has a factory set value. These values may be customiz

Page 40

43SYSTEM REPORTING CODES✦ Refer to the System Reporting Codes table to view/edit the reporting codes for the keypad FIRE and EMERGENCY buttons and fo

Page 41

444 BY 2 FORMAT POINT ID REPORTING CODES4 BY 2 FORMAT POINT ID ALARM REPORT CODES✦ Refer to the 4 by 2 Format Point ID Reporting Code table to view/e

Page 42

454 BY 2 FORMAT POINT ID REPORTING CODESSTEP # PROGRAMMING FUNCTION POSSIBLE 4 BY 2 VALUES FACTORY 4 BY 2 VALUE INSTALLATION 4 BY 2 VALUE210 SENSOR 1

Page 43

LINEAR LIMITED WARRANTYThis Linear product is warranted against defects in material and workmanship for twelve (12) months. This warranty extends only

Page 44 - STORES NEW VALUE

3DOOR/WINDOW SENSORSThe DXS-31 and DXS-32 sensors monitor doors and windows. They send radio signals to the Control Panel. One type of signal is sent

Page 45 - STORES VALUE - 1 BING

4EXAMPLE SYSTEM✦ The example shows a typical DUAL 824 system.✦ Any or all of the accessories shown can be used.✦ A total of 24 sensors can be used

Page 46

5HARDWIRED KEYPAD✦ One or two hardwired keypads can be used for controlling the system.✦ Three system status indicators:READY, ARMED, & TROUBLE✦

Page 47

61 BEAUTY COVER★ The beauty cover snaps open and shut to hide the keypad’s keys, mode and supervisory indicators, and the sensor location labeling ar

Page 48 - IMPORTANT INFORMATION

71 BATTERY FUSE★ Type 2AG, 3-amp fuse for the backup battery.★ If the keypad's POWER light is fl ashing and the optional backup battery is insta