6. BASIC CONSOLE PROGRAMMING
In a new installation,
when power is first applied
the Console’s master user code is “1234”.
CREATE THE MASTER USER CODE
NOTE: Local programming must be entered on the
Console’s keypad, not on a wireless remote keypad.
Press [
] (clears keypad if any other keys have
been pressed).
Place the Console in Test Mode (enter 1234 and
press [
TEST
].
A “gong” and four “beeps” will sound.
Enter the Setup Mode
from Test Mode
, enter
1234
then press [
TEST
] again.
A “gong” and five “beeps” will sound. You are
now in Setup Mode.
Enter 99 then press [
HOME
].
Enter any combination of 1-5 digits for the
master user code, then press [
AWAY
].
NOTE: For maximum security, a three to five digit
code is recommended.
Press and hold the [
OFF
] key for 3 seconds to
exit program mode.
Test the new master user code by entering it
then pressing [
TEST
].
Log the master user code in the box below.
MASTER USER CODE
NOTE: The master user code can be used to enter
Setup Mode. The restricted user codes cannot. To
create restricted user codes, see the “Advanced
Programming” section of this manual.
PROGRAM THE SENSORS INTO THE CONSOLE’S MEMORY
Each wireless sensor that is going to be used
with the Console must be programmed into the
Console’s memory.
Start with the Console in Test Mode (enter any
user code and press [
TEST
]).
Enter the Setup Mode
from Test Mode
, enter the
master user code
then press [
TEST
] again.
A “gong” and five “beeps” will sound. You are
now in Setup Mode.
The sensor status indicators will light for any
sensors programmed into the Console.
Enter an unused sensor number from 01-24
(you must enter two digits, example: 5 = 05)
The sensor indicator light will flash for the sensor
number selected.
Activate the sensor by sending a test or alarm
signal (be sure the sensor’s battery is connected
or that its battery protection strip is removed).
A single “bing” tone will sound and the sensor
status indicator for that sensor will stay lit.
Enter another sensor number or exit Setup Mode
by holding the [
OFF
] key for three seconds.
START IN OFF
DEFAULT
MASTER
USER
CODE
1 GONG &
4 BEEPS
(TEST MODE)
START IN SETUP
PROGRAMMING
STEP #99
NEW
MASTER
USER
CODE
DONE
HOLD FOR
3 SECONDS
TO EXIT
SETUP
STORE
CODE
ENTERING
SETUP
MODE
CLEARS
KEYPAD
DEFAULT
MASTER
USER
CODE
1 GONG &
5 BEEPS
(SETUP MODE)
SETTING A
NEW MASTER
USER CODE
PROGRAM
START IN TEST
MASTER
USER
CODE
1 GONG &
5 BEEPS
NEW
SENSOR
NUMBER
ACTIVATE
SENSOR
DONE