COMMUNICATOR REPORTING OPTIONS
REPORTING FORMAT
The factory setting causes the communicator to
report using the 4 by 2 format. This format
allows four-digit account numbers from 0000 to
9999 and provides two-digit alarm codes.
Alternately ADEMCO CONTACT ID can be
chosen as a reporting format. This format allows
4-digit account numbers from 0000 to 9999 and
provides verbose report descriptions with
Ademco Contact ID compatible Central Stations.
CALL ROUTING
The factory setting for the communicator is to
route all calls to the primary telephone number.
If communication is unsuccessful after five
attempts to the primary number, the secondary
number will be dialed for an additional five
attempts. If the secondary number cannot be
reached, the communicator will “sleep” for five
minutes before starting the call process over
again. A total of five sleep cycles (50 call
attempts) can occur before the communicator
stops calling.
Alternately, the communicator can be
programmed to report supervisory events (low
batteries, radio trouble, etc.) to the supervisory
telephone number instead of the primary or
secondary telephone numbers.
CAUTION: If the page alert user code feature is
going to be used, the supervisory number is
reserved for the pager number. DO NOT SET THE
CALL ROUTING OPTION TO “1”.
To disable supervisory reports, set call routing
option to “1” and remove the supervisory
telephone number or in 4 by 2 set the report to 0.
NOTE: Do not program the primary and secondary
telephone numbers the same. See the FCC
Telephone Rules and Regulations on the rear
cover of this manual.
COMMUNICATOR REPORTING OPTIONS
STEP #
PROGRAMMING
FUNCTION
POSSIBLE
VALUES
FACTORY
VALUE
INSTALLATION
VALUE
86 CALL ROUTING
0 = ALL CALLS TO PRIMARY OR SECONDARY NUMBER
1 = ALL ALARM CALLS TO PRIMARY OR SECONDARY NUMBER AND
ALL OTHERS TO SUPERVISORY NUMBER
0
88 ACCOUNT NUMBER 4 DIGITS EMPTY
89 PRIMARY PHONE NUMBER UP TO 20 DIGITS EMPTY
90 SECONDARY PHONE NUMBER UP TO 20 DIGITS EMPTY
91 SUPERVISORY/ PAGER PHONE NUMBER UP TO 20 DIGITS EMPTY
FOR ALL PHONE NUMBERS
⇒⇒⇒⇒
PRESSING THE (A) KEY INSERTS A 1-SECOND DELAY
THE [FIRE] KEY INSERTS A 5-SECOND DELAY
THE [CHIME] KEY INSERTS A “
*
THE (A) KEY INSERTS A “#” IF IT IS THE LAST DIGIT OF THE PHONE
NUMBER
105 REPORTING FORMAT 0 = 4 BY 2; 1 = ADEMCO 0
108 REPORT CONSOLE TROUBLE 0 = NO; 1 = YES 0
110 REPORT FORCE ARMING 0 = NO; 1 = YES 0
111 OPEN/CLOSE 0 = NO; 1 = YES; 2 = MASTER PAC ONLY 0
113 POINT ID REPORTING FOR 4 BY 2 FORMAT 0 = NO; 1 = YES 1
Communicator Reporting Option Table
0
5
JKL
HOME
AWAY
0 FOR 4 BY 2
1 FOR ADEMCO CONTACT ID
PROGRAMMING STEP #105
PROGRAM
STORE PROGRAM
1
8
TUV
6
MNO
HOME
AWAY
PROGRAMMING STEP #86
PROGRAM
STORE PROGRAM
0 FOR ALL TO PRIMARY/SECONDARY
1 FOR ALARMS ONLY TO
PRIMARY/SECONDARY